Dry Contact Industrial Water Leak Detector

SPD-WL02-Pro the non-locating leak detection controller is a water leak detection device with simple operation and high cost performance. User can select different sensing sensitivities through the DIP switch on the panel to be used in different detection environments and grade requirements.

It can be integrated with various monitoring systems to realize remote monitoring with a relay contact signal output.

Availability:
Quantity:


The Dry Contact Water Leak Detector SPD-WL02-PRO is a cost-effective, user-friendly solution for water leak detection in critical environments. As a non-locating leak detector, it prioritizes reliable alarm triggering to mitigate the risk of water damage in facilities where even minor leaks can lead to costly downtime, equipment failure, or data loss. Engineered with industrial-grade components and flexible integration capabilities, this detector is an indispensable tool for server rooms, data centers, pump rooms, and other spaces requiring continuous leak monitoring. Its simple operation, adjustable sensitivity, and robust performance make it suitable for both professional technicians and facility managers seeking a low-maintenance yet effective water leak solution.


dry contact water leak detector



Features


Stable & Reliable Performance

Constructed with industrial-grade electronic components, the Dry Contact Water Leak Detector delivers consistent, high-sensitivity detection while minimizing false alarms caused by external factors such as dust, humidity, or electrical interference. It adopts an electromagnetic compatibility design, incorporating anti-surge, anti-static, and anti-EFT protection to ensure stability in harsh industrial or data center environments.


Adjustable Sensing Sensitivity

The detector features a 2-position 4-gear DIP switch on the front panel, allowing users to customize sensing sensitivity to match their specific environment and detection requirements. This flexibility enables it to adapt to different scenarios—from sensitive server rooms where even small leaks must be detected to industrial areas where higher tolerance for minor moisture is acceptable.


Easy Operation & Installation

Designed with standard industrial modules and DIN rail mounting, the detector can be easily installed and wired on-site using accessible terminals. It requires no complex programming or specialized training to operate: when a leak is detected, the relay activates automatically, and the leakage indicator illuminates. Once the leak is resolved, the detector resets to normal operation without manual intervention.


Local Sound and Light Alarm

Upon detecting liquid leakage, the detector triggers a local sound and light alarm: the panel’s LED leakage indicator remains illuminated, and an internal buzzer emits a loud, audible alert. This dual warning system ensures that on-site personnel are immediately notified of leaks, enabling rapid response to minimize damage.


One-Key Mute Function

For situations where the audible alarm may be disruptive (e.g., after personnel have been alerted and are addressing the leak), the detector includes a one-key mute function. A dedicated button on the panel allows users to silence the buzzer while maintaining the illuminated LED indicator, ensuring visibility of the alert without unnecessary noise.


Remote Monitoring Integration

Equipped with a dry contact relay output, the Dry Contact Water Leak Detector can be seamlessly integrated with various third-party monitoring systems, including building management systems (BMS) and security platforms. This enables remote monitoring of leak status, allowing users to receive alerts and manage the system from off-site locations.



Core Specifications


Detection Performance

Response Capability: Delivers fast, reliable response to liquid contact, ensuring that leaks are detected promptly to prevent extensive damage.

Detection Coverage: Designed to work with non-location water leak sensing cables, providing comprehensive coverage across large areas or critical equipment zones.


Power & Connectivity

Power Requirements: Supports a wide range of DC power inputs, making it compatible with standard industrial power supplies and backup systems.

Output Interface: Dry contact relay output (NO/NC) for integration with third-party devices such as sirens, alarms, or monitoring platforms.

Communication: Operates as a dry contact sensor, using simple relay signals for reliable, low-latency communication with connected systems.


Physical & Environmental Design

Dimensions: Compact, space-saving design that fits easily in standard DIN rail enclosures or equipment cabinets.

Installation Type: DIN rail mounting for straightforward integration into existing facility infrastructure.

Operating Environment: Tolerates a wide range of temperatures and humidity levels (without condensation), ensuring performance in diverse indoor settings.


Durability & Protection

Component Quality: Industrial-grade components selected for long-term reliability and resistance to wear, dust, and minor environmental stressors.

Electromagnetic Protection: Equipped with anti-surge, anti-static, and anti-EFT features to withstand electrical interference in industrial or data center environments.


Response Time

≤1S

Detection Distance

500m

Operating temperature

-20°C~70°C

Operating humidity

0%~95% RH(no condensing)

Power supply

9V -30V DC

Power Consumption

≤0.5W

Relay

Dry contact, NO/NC

Load: 120V AC/2A, 24V DC/2A

Dimension

84*38*56.5 mm

Installation

DIN rail



Applications


The Dry Contact Water Leak Detector is ideal for water leak detection in environments where water damage could have severe consequences:

Server Rooms: Protects servers, storage devices, and networking equipment from leaks caused by HVAC systems, pipe failures, or condensation.

Data Centers: Monitors critical areas such as air conditioner drip pans, raised floors, and equipment racks, preventing water damage to mission-critical IT infrastructure.

Pump Rooms & Mechanical Closets: Detects leaks from pumps, pipes, or valves, ensuring that mechanical failures do not lead to flooding or equipment damage.

Industrial Facilities: Monitors areas around water-cooled machinery, chemical storage tanks, or plumbing systems, mitigating risks of production downtime or safety hazards.

Commercial Buildings: Protects electrical panels, elevator shafts, and basement areas from leaks, safeguarding building infrastructure and occupant safety.



FAQ


How does the Dry Contact Water Leak Detector work?

The detector works in conjunction with a non-location water leak sensing cable. When the cable comes into contact with water, it creates a short circuit, which the detector recognizes as a leak signal. The detector then activates the local sound and light alarm and sends a dry contact (NO/NC) output signal to third-party devices such as sirens, BMS systems, or monitoring platforms to trigger further actions.


Does the detector support Modbus protocol?

No, this is a dry contact sensor and does not support Modbus protocol. It uses simple relay contact signals for communication, which ensures reliable integration with a wide range of third-party systems without the need for complex protocol configuration.


Can the detector identify the exact location of a leak?

No, this is a non-locating leak detector. It is designed to alert users to the presence of a leak but does not provide precise location data. For applications requiring leak localization, a dedicated locating water leak detector and sensing cable would be necessary.


How do I adjust the sensing sensitivity?

The detector features a 2-position 4-gear DIP switch on the front panel. You can adjust sensing sensitivity by toggling these switches, with options ranging from high sensitivity (for detecting small leaks) to lower sensitivity (for reducing false alarms in humid environments). Refer to the user manual for specific switch configurations.


Previous: 