High Stability: It adopts industrial-grade electronic components, ensuring high sensitivity during detection while reducing false alarms caused by various external factors. It features electromagnetic compatibility design with protection functions against surges, static electricity, and EFT.
Communication Method: The controller outputs RS485 signals to report real-time environmental monitoring data, with a communication distance of up to 1200 meters.
Comprehensive Functions: The SPD-1088 controller has functions such as fault (disconnection) alarm, leakage alarm, and interference alarm. The controller's status can be displayed through interface indicator lights. When a leakage occurs, the relay acts, the leakage indicator light turns on, and the controller automatically returns to the normal state after the hazard is eliminated, without the need for on-site manual operation.
Installation: The SPD-1088 controller is suitable for standard DIN 35mm industrial rail installation, and all on-site wiring can be easily completed through terminal blocks.
| Parameter Item | Specification |
|---|---|
| Product Dimensions | 867056.5mm |
| Operating Voltage | DC9~30V wide voltage supply, recommended to use DC12V power supply, power consumption <0.5W |
| Detection Accuracy | ±0.5m + 1%, reading accuracy 0.1m |
| Detection Distance | 150m, response time ≤ 8s |
| Interface Type | RS485 |
| Communication Protocol | MODBUS-RTU, MODBUS-ASCII adaptive |
| Operating Temperature | -40℃~70℃ |
| Operating Humidity | 0~95%RH (no condensation) |
| EMC Protection | Contact discharge ±8KV, air discharge ±15KV, ±4KV surge, ±4KV EFT |
Industries: Finance, communication, government, transportation, logistics, factories, warehouses, pharmaceuticals, etc.
Application Scenarios: Computer rooms, warehouses, distribution rooms, factories, workshops, laboratories, etc., such as PLC control systems, elevator control systems, air conditioning automatic control systems, traffic automation control, computer room monitoring, power monitoring, security monitoring systems, anti-theft alarm systems, power environment monitoring systems, etc.
High Stability: It adopts industrial-grade electronic components, ensuring high sensitivity during detection while reducing false alarms caused by various external factors. It features electromagnetic compatibility design with protection functions against surges, static electricity, and EFT.
Communication Method: The controller outputs RS485 signals to report real-time environmental monitoring data, with a communication distance of up to 1200 meters.
Comprehensive Functions: The SPD-1088 controller has functions such as fault (disconnection) alarm, leakage alarm, and interference alarm. The controller's status can be displayed through interface indicator lights. When a leakage occurs, the relay acts, the leakage indicator light turns on, and the controller automatically returns to the normal state after the hazard is eliminated, without the need for on-site manual operation.
Installation: The SPD-1088 controller is suitable for standard DIN 35mm industrial rail installation, and all on-site wiring can be easily completed through terminal blocks.
| Parameter Item | Specification |
|---|---|
| Product Dimensions | 867056.5mm |
| Operating Voltage | DC9~30V wide voltage supply, recommended to use DC12V power supply, power consumption <0.5W |
| Detection Accuracy | ±0.5m + 1%, reading accuracy 0.1m |
| Detection Distance | 150m, response time ≤ 8s |
| Interface Type | RS485 |
| Communication Protocol | MODBUS-RTU, MODBUS-ASCII adaptive |
| Operating Temperature | -40℃~70℃ |
| Operating Humidity | 0~95%RH (no condensation) |
| EMC Protection | Contact discharge ±8KV, air discharge ±15KV, ±4KV surge, ±4KV EFT |
Industries: Finance, communication, government, transportation, logistics, factories, warehouses, pharmaceuticals, etc.
Application Scenarios: Computer rooms, warehouses, distribution rooms, factories, workshops, laboratories, etc., such as PLC control systems, elevator control systems, air conditioning automatic control systems, traffic automation control, computer room monitoring, power monitoring, security monitoring systems, anti-theft alarm systems, power environment monitoring systems, etc.